{"product_id":"uts3000b-ama","title":"UTS3000-AMA","description":"\u003ch3\u003eWhy Choose the UTS3000-AMA Analog Demodulation Analysis Option?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTS3000-AMA\u003c\/strong\u003e \u003cem\u003eAnalog Demodulation Analysis\u003c\/em\u003e option is designed for engineers who demand precise, high-frequency signal analysis. With support for demodulation across an expanded frequency range up to 8.4 GHz, this option caters to cutting-edge applications in telecommunications, aerospace, and advanced RF system development. Its ability to measure AM, FM, and PM signals with unmatched accuracy ensures engineers can easily characterize complex modulated signals, optimize performance, and maintain compliance with industry standards. Built directly into the \u003cstrong\u003e\u003ca title=\"Learn more about the UNI-T UTS3000B Series of Spectrum Analyzers\" href=\"https:\/\/uni-trendus.com\/collections\/uts3000b\"\u003eUNI-T UTS3000-series spectrum analyzers\u003c\/a\u003e\u003c\/strong\u003e, this tool eliminates the need for external equipment, saving both lab space and project budgets.\u003c\/p\u003e\n\u003cp\u003eFor instance, a radar system engineer testing phase-modulated (PM) signals for a next-generation communication platform can rely on the \u003cstrong\u003eUTS3000-AMA\u003c\/strong\u003e for quick and accurate measurements. Without this option, the process would require intricate setups to manually calculate phase deviation and modulation rate, using multiple instruments and risking data inconsistencies. With the AMA option, the engineer can instantly analyze phase deviations of up to 6.28 radians and modulation rates from 20 Hz to 100 kHz, achieving precise insights into signal behavior. This efficiency not only accelerates product development but also reduces costs associated with redundant testing and hardware, making it an essential investment for advanced RF applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUNI-T UTS3000-AMA Analog Demodulation Analysis Option\u003c\/h3\u003e\n\u003ch4\u003eDemodulation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range\u003c\/strong\u003e (Spectrum Analyzer Model Dependent):\n\u003cul\u003e\n\u003cli\u003e2 MHz to 2.1 GHz\u003c\/li\u003e\n\u003cli\u003e2 MHz to 3.6 GHz\u003c\/li\u003e\n\u003cli\u003e2 MHz to 8.4 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Power Accuracy\u003c\/strong\u003e: ±2 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: -30 dBm to +20 dBm (Automatic attenuation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Power Display Resolution\u003c\/strong\u003e: 0.01 dBm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAM Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulation Rate\u003c\/strong\u003e: 20 Hz to 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 Hz (Nominal) for Modulation Rate \u0026lt; 1 kHz\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 0.1% Modulation Rate (Nominal) for Modulation Rate ≥ 1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 5% to 95%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth Accuracy\u003c\/strong\u003e: ±4% (Nominal)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFM Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulation Rate\u003c\/strong\u003e: 20 Hz to 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 Hz (Nominal) for Modulation Rate \u0026lt; 1 kHz\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 0.1% Modulation Rate (Nominal) for Modulation Rate ≥ 1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Offset\u003c\/strong\u003e: 1 kHz to 400 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Offset Accuracy\u003c\/strong\u003e: ±4% (Nominal)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePM Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulation Rate\u003c\/strong\u003e: 20 Hz to 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 Hz (Nominal) for Modulation Rate \u0026lt; 1 kHz\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 0.1% Modulation Rate (Nominal) for Modulation Rate ≥ 1 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Deviation\u003c\/strong\u003e: 0.2 to 6.28 rad\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Deviation Accuracy\u003c\/strong\u003e: ±4% (Nominal)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":46901473214748,"sku":"191500200001","price":319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTS3000-AMA.png?v=1717686117","url":"https:\/\/uni-trendus.com\/products\/uts3000b-ama","provider":"Uni-Trend US","version":"1.0","type":"link"}